Nayax Card Reader Troubleshooting Guide for Vending Machines

Tired of Nayax Card Reader Issues? VapeTM Has the Solution

Are you constantly dealing with Nayax card reader errors?

M00, M01, V00, V01, V02, RSSI 99 authorization declinedโ€”sound familiar?

You swipe a cardโ€ฆ nothing happens. No prompt. No transaction. Just frustration.

You troubleshoot, troubleshoot, troubleshootโ€ฆ

Wait hours for a Nayax repโ€”if they call back. Cross your fingers, hope it gets fixedโ€ฆ Then the same problem happens all over again.

Whatโ€™s the real issue? Whatโ€™s the real solution?

VapeTM is here to provide permanent solutions to your Nayax card reader issues. We go beyond troubleshootingโ€”we identify the root causes and fix them for good!

As anย OEM distributor of Nayax, VapeTM doesnโ€™t just troubleshootโ€”we fix the problem at its core and provide permanent solutions.

We go beyond just telling you whatโ€™s wrongโ€”we explain why itโ€™s happening and how to prevent it for good.ย 

If you are experiencing trouble with your AI smart cooler,ย ReyVend has an excellent guide on troubleshooting errors codes as it relates to smart cooler equipped with pre-authorization.ย ย 

With Our Support, Youโ€™ll Learn How To:

    • ย โœ… Assign payment IDs
    • ย โœ… Reset Parameters and Reload configuration files
    • ย โœ…Change Settings for your specific protocol (ie. MDB Level 3)
    • ย โœ… Add a payment kernel
    • ย โœ… Optimize your card reader for seamless transactions

Weโ€™ll Also Guide You Through:

  • ย ๐Ÿ”น Locating and updating your firmware
  • ย ๐Ÿ”น Performing factory resets
  • ย ๐Ÿ”น Setting up unique, cloneable payment IDs for future machines

Smart Vending Starts Here

VapeTM specializes in cashless payment solutions and advanced Nayax technical support. Whether you're facing recurring issues or setting up new machines, we are here to make your experience smooth and your cashless transactions stable.ย 

Complete Nayax Error Codes and Troubleshooting Guide



Problem: The Nayax card reader does not prompt for payment (it does nothing) and does not say โ€œplease insert your cardโ€.ย 

Solution: Check MDB Settings change them if necessary and then perform a power cycle.

MDB Settings:ย 
1. MDB Parameters:ย 
Ignore VMC Configuration: Enabled (ON)
2. MDB Flags:ย MDB Flags: 06 Ignore + Pre Selection


V00: No Communication

Cashless out of order error showing V00 machine on Nayax vending machine
  1. Meaning: No communication between the machine and the Nayax device. ย 
  2. Solutions:
    • Technician Mode: Enter Technician Mode on the card reader (password: 123123 or 8 ).
    • Factory Reset: Perform a factory reset via the reader menu.
    • Default Parameters Reset: Use the Nayax web application to reset default parameters.
    • Inspect Cables: Ensure MDB cables are securely connected and undamaged.
    • Contact Support: If unresolved, consult VapeTM or Nayax support.

Basic Communication Troubleshooting:

  1. Power Off the Vending Machine
    • Locate the SIM card on the left side of the device.
    • Pull down the metal bracket, remove the SIM card, and reinsert it properly (cut corner on the upper side).
    • Ensure the SIM card slot is securely closed.
  2. Check the Antenna Connection
    • Unplug the antenna from its port and replug it firmly until you hear a "click."
    • Ensure the antenna is still positioned on top of the vending machine or as high as possible.
  3. Factory Reset the Device
    • Once the Nayax logo appears, press the menu button (three horizontal lines).
    • Select Technician Mode and enter the password 123123.
    • Scroll down and select FACTORY RESET.
    • The device will restart and should return to the tap/scan to pay screen.
If the issue persists:
  • Try a Webbing SIM Card
    • If Verizonโ€™s coverage is still weak, switch to a Webbing SIM card ($2.50 + shipping via UPS).
    • Webbing SIM can connect to Verizon, AT&T, or T-Mobile, offering better reception in congested areas.

Webbing Sim Card Streamlining Global Data Connectivity

  • Use a High-Gain Antenna
    • If the signal does not improve with an AT&T/T-Mobile network switch, consider a high-gain antenna ($30 + shipping via UPS).
    • This is recommended for weak signal areas and requires secure installation on top of the vending machine.

VapeTM Nayax high gain cellular antenna designed for enhanced connectivity in vending machine systems.

V01: MDB Configuration Issueย 

Cashless payment reader showing โ€œCashless out of orderโ€ with V01 machine fault and QR code on a Nayax device

  • Meaning: MDB settings are misconfigured.
  • Solutions:
    1. Access MDB Settings: Use the Nayax web portal to verify MDB settings.
    2. Select โ€œ06 Ignore Pre-Selectionโ€:
      • Save settings and initiate an update via the Update Queue.
    3. Restart Machine: Unplug the machine for 3 minutes, then reconnect power.
    4. Check Firmware: Update the vending machine and Nayax firmware.
    5. Contact Support: If unresolved, consult VapeTM support.
V02: Cashless Payments Disabled
  • Meaning: The machine sent a โ€œReader Disableโ€ command due to a communication issue.
  • Solutions:
    1. Restart the Machine: Power off for 3 minutes and then power back on.
    2. Enable Reader: Re-enable cashless functionality via the Nayax web application.
    3. Inspect SIM Card: Reseat the SIM card and verify proper installation.
    4. Contact Support: Contact VapeTM Support for troubleshooting.
M01: MDB Device Not Responding
M01 Nayax Error Code
  • Meaning:ย  The card reader cannot communicate with the vending machine controller.
  • Solutions:
    1. Check Connections: Inspect all MDB cables for secure connections and damage.
    2. Restart Machine: Power cycle the vending machine.
    3. Configure MDB Settings: Use the Nayax portal to verify MDB Level 3 settings.
    4. Firmware Update: Update firmware on both the machine and the Nayax reader.
    5. Contact Support: Reach out to VapeTM or Nayax support.
M02: Reader Disabled
M02 Nayax Error Code
  • ย Meaning: Communication is blocked due to an MDB misconfiguration.
  • Solutions:
    1. Enable Reader: Re-enable the reader in the Nayax portal.
    2. Power Cycle: Restart the machine to reset connections.
    3. Inspect Hardware: Check and reseat the MDB cable.
    4. Contact Support: Contact VapeTM or Nayax support if the issue persists.

M05 โ€“ No Server Connection

The device cannot establish a connection with the Nayax server.
Solution:
  1. Check the SIM Card:
    • Turn off the vending machine.
    • Open the Nayax terminal and remove the SIM card.
    • Wipe the contacts with a dry cloth.
    • Reinsert the SIM card and turn the machine back on.
  2. Check the Antenna & Signal Strength:
    • Ensure the antenna is securely connected.
    • Relocate the antenna to improve signal reception.
    • If damaged, replace the antenna.
  3. Restart the Nayax Terminal:
    • Access Technician Mode on the Nayax terminal.
    • Enter the password.
    • Scroll down and select Restart.
  4. Restart via the MoMa App:
    • Open the app and select the vending machine.
    • Go to Tasks and Warnings, select Actions, then Restart Device.
RSSI Signal Strength Issues or Cash Only Display
  • Indicator:
    • 99 RSSI: No communication.
    • RSSI < 18: Poor signal strength.
  • Solutions:
    1. Enable Cashless: Verify that cashless settings are enabled in the Nayax portal.
    2. Hardware Check:ย  Confirm all MDB and antenna connections are secure.
    3. Check Antenna: Ensure the antenna is securely connected to the reader.
    4. Check and reseat SIM card: Ensure that the SIM card is correctly inserted into the back of the device.ย  Remove the SIM card and re-insert it. ย If possible, take a known working SIM card and see if this fixes the issue.ย 
      Make sure it is like for like SIM, meaning: replace a Verizon SIM for Verizon (Verizon SIM card begins with 89148) and Non-Verizon SIM for Non-Verizon.
    5. Upgrade Antenna: ย Install a high-gain antenna if signal strength is weak or make sure the antenna is correctly connected to the antenna port.ย  You may also move the antenna and relocate it to a high locaiton outside the vending machine (ie. on top of the vending machine).ย ย 
    6. Reboot the Device:ย Unplug the machine for 2 minutes and plug it back in and wait a few minutes for everything to reload.ย  Test again.
    7. Monitor Signal: Use the Moma App or Nayax web portal to view RSSI history and fluctuations.
    8. Contact Support: ย If unresolved, VapeTM can assist with carrier changes or SIM replacement.

General Troubleshooting for MDB Level 3 Vending Machinesย 

MDB (Multi-Drop Bus) Level 3 is a standard for communication between vending machines and peripherals. Hereโ€™s how to maintain compatibility and performance:
  • Check Compatibility: Ensure both the vending machine and Nayax reader support MDB Level 3.
  • Verify Settings: Use the Nayax portal to confirm correct MDB configurations.
  • Inspect Physical Connections: Check MDB cables for proper installation and signs of damage.
  • Update Firmware: Regularly update firmware on both the vending machine and the Nayax device.
  • Monitor Error Logs: Use the Nayax web portal to view detailed error logs for diagnostics.
  • Perform Signal Tests: Regularly test RSSI signal strength using the Moma App or Nayax reader menu.
    Aย DEX Failed error means the Nayax terminal cannot transmit data.

    Steps to Fix:

    1. Restart the Vending Machine:
      • Open the vending machine.
      • Turn off the power for 30 seconds.
      • Turn it back on and retry DEX transmission.
    2. Restart the Nayax Terminal:
      • Access Technician Mode on the Nayax device and restart.
      • OR, use the MoMa App to restart remotely.
    3. Check DEX Cable & Connections:
      • Verify that the DEX cable is securely connected.
      • If damaged, replace it.
    4. Manually Reload Data in the MoMa App:
      • Open the MoMa App.
      • Navigate to More โ†’ Last Data Update.
      • Select Reload Data.
    5. Replace the Nayax Terminal (Final Step):
      • Turn off the vending machine.
      • Remove and replace the Nayax device.

    Best Practices:

    Power & Hardware Issues

    Power Down Error If the machine has lost power, it may be due to:
    • Power outage
    • Loose power connection
    • Defective power supply
    Solution:
    • Ensure the vending machine is plugged in.
    • Check the Nayax terminal power connection.
    • If necessary, replace the power supply unit.
    Antenna Disconnected from Circuit Board
    • Open the vending machine.
    • Disconnect power before handling electronics.
    • Ensure the antenna is securely connected to the circuit board.
    • Reconnect the antenna if loose.
    How to Restart the Nayax Terminal
    1. Using the Terminal Itself:
      • Press the menu button (three lines).
      • Navigate to Technician Mode.
      • Enter your password.
      • Select Restart.
    2. Using the MoMa App:
      • Select the machine in the app.
      • Go to Tasks and Warnings โ†’ Actions โ†’ Restart Device.
    How to Clean the SIM Card
    1. Turn off the vending machine.
    2. Open the Nayax terminal and locate the SIM card.
    3. Remove the SIM card and wipe the contacts with a dry cloth.
    4. Reinsert the SIM card and close the terminal.
    5. Restart the vending machine.
      • Proactive Maintenance: Regularly inspect connections and monitor device status via the Nayax portal.
      • Stay Updated: Keep firmware up-to-date to ensure seamless operation.
      • Training Resources: Refer to Nayaxโ€™s online manuals and VapeTMโ€™s training videos ย for setup and maintenance.
    Back to blog

    10 comments

    I really like the intersection and it is very easy to understand thank you

    Joel K Smith

    RSSI 99: Easy guide to followโ€ฆ

    In the world of Nayax, RSSI 99 means โ€œNo Communication.โ€ Use this simplified guide to get your machine back online.

    Step 1: Check the Antenna Connection
    Ensure the antenna cable is firmly popped/clicked into the port on the back of the Nayax unit.

    This is usually a snap-on connector (not a threaded screw).

    It should feel seated firmly and not wiggly.

    Step 2: Position the Antenna Pole
    The cable leads to a magnetic base.

    Make sure the antenna pole (the stick part) is screwed tightly onto that base.

    Place the base on the top of the vending machine (outside).

    Important: Ensure the cable is not being pinched when you close the vending machine door. You may need to shift the magnetic base to align the cable with a hole or gap.

    Step 3: Clean and Reseat the SIM Card
    If the antenna is fine, the device may not be โ€œtalkingโ€ to the SIM card.

    Power Down: Turn off the vending machine power entirely.

    Locate & Remove: Find the SIM slot on the side of the unit. Slide the metal bracket to the Open position and remove the SIM.

    The Cleaning Trick: Use a soft cloth or a pencil eraser to gently clean the gold contacts. Oils or dust can cause connection drops.

    Reseat: Place the SIM back in (ensure the notched corner is oriented correctly). Slide the metal bracket back to the LOCK position.

    Step 4: The โ€œHardโ€ Power Cycle
    A simple menu reboot often isnโ€™t enough to reset a hung cellular modem.

    Unplug the Reader: Disconnect the MDB cable (the main white or black multi-pin plug) from the back of the Nayax unit.

    The Wait: Keep the unit unplugged for at least 3 full minutes. This allows the internal power to drain completely.

    Reconnect: Plug the MDB cable back in and power the machine on.

    Patience: Wait 5โ€“10 minutes. The device will show โ€œInit Modemโ€ or โ€œPlease Wait.โ€ It takes time to scan for towers and clear the 99 code.

    Signal Strength Guide
    Once the 99 is gone, check your numbers:

    1โ€“12: Critical (Very poor connection)

    13โ€“19: Fair (Stable)

    20โ€“31: Excellent (Optimal)

    Jordan

    I have a Nayax with high gain antenna at the location with poor reception. My RSSI stayed around 13 and I need something to raise it above 15. Is there any way you can recommend to fix the reception issue?

    Stephen Mooney

    Kiosoft has cheaper fees and support Amex. Now at 2.9% and 15 cents and VapeTM does pre-programming! Ultimately, a game changer in smart digital vending. Learn more at VapeTM.com

    Jordan

    So Kiosoft is better than Nayax?

    Jason

    Leave a comment